Vision Controls Cam SS Version 5.01 Instrukcja Obsługi Strona 67

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 76
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 66
53
Appendix A
A.1 Configuring the In-Sight Sensors I/O Settings
Before an I/O Expansion Module can be used, the In-Sight sensors settings must be
configured to recognize the availability of the additional inputs and outputs, as well as the
added serial hardware handshaking capability. The I/O Expansion Module may be
configured using In-Sight Explorer.
A.1.1 Configuring the I/O Expansion Module Using In-Sight Explorer
1. Physically connect the I/O Expansion Module to the sensor, as described in sections 3.3 and
3.4.
2. Open In-Sight Explorer and log on to the sensor.
3. From the Sensor menu, select the Discrete I/O Settings submenu. Select the Output Settings
option (
Figure A-1).
Figure A-1: Accessing the I/O Output Settings
4. Open the Output Module drop-down list at the bottom left of the window (Figure A-2) and
select I/O Expansion Module. The Discrete Output window will automatically reconfigure to
correspond to the I/O Expansion Module.
5. Configure the Line Name, Type and Details as required.
Przeglądanie stron 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 75 76

Komentarze do niniejszej Instrukcji

Brak uwag